: Set the boom between 0 and 5 degrees. Use an inclinometer to verify the actual physical angle.
: Test that the system successfully disables crane functions during an overload condition. n_031.mp4
The angle sensor ensures the crane's boom is at the correct pitch for safe lifting. : Set the boom between 0 and 5 degrees
: Fully retract the boom. Turn the potentiometer counter-clockwise until it stops to reset the "zero" point. n_031.mp4
: Check the angle display at 20°, 45°, and 70°. The display must be within ±0.5 degrees of the inclinometer reading.